B7-30-01-80
B7-30-01-80
 Loading Images..
Feedback Comments and Assessment
Excellent
Good
Poor
Cancel
Send feedback  
Back to search results
Print View..    Print to Pdf..

B7-30-01-80

GJL1311001R8010
 Loading Images..
  1. Products
  2. Low Voltage Products and Systems
  3. Control Products
  4. Contactors
  5. Mini Contactors
- Show Less..
No label translation
General Information
Extended Product Type:
B7-30-01-80
Product ID:
GJL1311001R8010
EAN:
4013614152047
Catalog Description:
B7-30-01-80 Mini Contactor 220 ... 240 V AC - 3 NO - 0 NC - Screw Terminals
Long Description:
The B7-30-01 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A (AC-1) or switching of control signals. Further features are the silent coil, a switch position indication and the integrated possibility for rail or wall mounting.
  • Details
  • Downloads
  • Related Links
Go to section:
Navigate:
  • Back to top
  • Back to search results
Ordering
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080
Popular Downloads
EPLAN Data:
9AAC201023_EPLAN
Data Sheet, Technical Information:
1SBC100214C0202
Instructions and Manuals:
2CDC102047M6801
CAD Dimensional Drawing:
2CDC001079B0201
Dimensions
Product Net Width:
52.5 mm
Product Net Depth / Length:
46.7 mm
Product Net Height:
57.5 mm
Product Net Weight:
0.175 kg
Dimension Diagram:
GJL1200436F0001
Technical
Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
1
Number of Poles:
3P
Standards:
IEC/EN 60947-1

IEC/EN 60947-4-1

IEC/EN 60947-5-1

UL 60947-1

UL 60947-4-1

IEC 60335-2-40 A2L
Rated Operational Voltage:
Auxiliary Circuit 690 V AC

Auxiliary Circuit 250 V DC

Main Circuit 690 V AC

Main Circuit 220 V DC
Rated Frequency (f):
Control Circuit 400 Hz

Control Circuit 50 Hz

Control Circuit 60 Hz

Main Circuit 50 Hz

Main Circuit 60 Hz

Main Circuit DC
Conventional Free-air Thermal Current (Ith):
Main Circuit 20 A
Rated Operational Current AC-1 (Ie):
(220 / 240 V) 40 °C 20 A

(220 / 240 V) 55 °C 16 A

(380 / 440 V) 40 °C 20 A

(380 / 440 V) 55 °C 16 A

(690 V) 40 °C 6 A

(690 V) 55 °C 6 A
Rated Operational Current AC-3 (Ie):
(230 V) 55°C 12 A

(400 V) 55 °C  12 A

(500 V) 55 °C 9 A

(690 V) NO 55°C 3.5 A
Rated Operational Current AC-15 (Ie):
(24 V) 4 A

(120 V) 4 A

(500 V) 2 A

(220 / 240 V) 4 A

(380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie):
(24 V) 2.5 A

(110 V) 0.7 A

(220 / 240 V) 0.4 A
Rated Operational Power AC-3 (Pe):
(230 V) Three Phase 3 kW

(400 V) Three Phase 5.5 kW

(500 V) Three Phase 5.5 kW

(690 V) Three Phase, NO 3 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
Rated Insulation Voltage (Ui):
690 V

acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
Auxiliary Circuit 6 kV

Main Circuit 6 kV
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour

(AC-15) 600 cycles per hour

(AC-3) 600 cycles per hour

(DC-1) 600 cycles per hour

(DC-13) 600 cycles per hour

(DC-3) 600 cycles per hour
Mechanical Durability:
Nr. Operations 10000000 cycle
Minimum Switching Capacity:
Auxiliary Circuit 17 V

Auxiliary Circuit 5 mA
Coil Operating Limits:
(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
220 ... 240 V AC
Coil Consumption:
Average Holding Value 50 Hz 3.5 V·A

Average Pull-in Value 50 Hz 3.5 V·A
Power Loss:
at Rated Operating Conditions AC-1 per Pole 1.4 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715

TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²

Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²

Flexible 1/2x 1 ... 2.5 mm²

Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²

Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²

Flexible 1/2x 1 ... 2.5 mm²

Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²

Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²

Flexible 1/2x 1 ... 2.5 mm²

Rigid 1/2x 1 ... 4 mm²
Wire Stripping Length:
Auxiliary Circuit 9 mm

Main Circuit 9 mm
Degree of Protection:
Auxiliary Circuit Terminals IP20

Control Circuit Terminals IP20

Main Circuit Terminals IP20
Recommended Screw Driver:
M3

Pozidriv 1
Tightening Torque:
Auxiliary Circuit 0.8 ... 1.1 N·m

Control Circuit 0.8 ... 1.1 N·m

Main Circuit 0.8 ... 1.1 N·m
Terminal Type:
Screw Terminals
Mini Contactor Type:
Mini Contactor
Product Name:
Mini Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
General Use Rating UL/CSA:
(600 V AC) 16 A
Horsepower Rating UL/CSA:
(115 V AC) Single Phase 0.75 Hp

(200 V AC) Three Phase 2 Hp

(220 ... 240 V AC) Three Phase 3 Hp

(230 V AC) Single Phase 1.5 Hp

(440 ... 480 V AC) Three Phase 5 Hp

(550 ... 600 V AC) Three Phase 5 Hp
Connecting Capacity Main Circuit UL/CSA:
Stranded 1/2x 22-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA:
Stranded 1/2x 22-10 AWG
Contact Rating UL/CSA:
A600
Tightening Torque UL/CSA:
Auxiliary Circuit 7 in·lb

Control Circuit 7 in·lb

Main Circuit 7 in·lb
Full Load Amps Motor Use:
(115 V AC) Single Phase 13.8 A

(200 V AC) Three Phase 7.8 A

(220 ... 240 V AC) Three Phase 9.6 A

(230 V AC) Single Phase 10 A

(440 ... 480 V AC) Three Phase 7.6 A

(550 ... 600 V AC) Three Phase 6.1 A
Environmental
Ambient Air Temperature:
Operation -25 ... +55 °C

Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Resistance to Vibrations:
5g 5 ... 150 Hz
Material Compliance
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
REACH Declaration:
2CMT2021-006202
RoHS Declaration:
2CMT2021-006277
RoHS Information:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA:
2CMT2023-006525
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
End Of Life Disassembling Instructions:
1SBC100156C0269
Environmental Product Declaration - EPD:
1SAC200409H0001
Certificates and Declarations
A2L Certificate – IEC:
1SAA938000-4601
BV Certificate:
1SAA920000-0204
CB Certificate:
1SAA938000-2002
CQC Certificate:
CQC2003010304064033
Declaration of Conformity - CCC:
2020980304001854
Declaration of Conformity - CE:
1SAD101100-3101
Declaration of Conformity - UKCA:
1SAD201100-3101
DNV GL Certificate:
1SAA938000-0306
EAC Certificate:
1SAA920000-2702
KC Certificate:
1SAA938000-1501
LR Certificate:
1SAA938000-0504
RMRS Certificate:
1SAA938000-0704
UL Certificate:
E191658-19881208
Container Information
Package Level 1 Units:
box 10 piece
Package Level 1 Width:
115 mm
Package Level 1 Depth / Length:
280 mm
Package Level 1 Height:
54 mm
Package Level 1 Gross Weight:
1.82 kg
Package Level 1 EAN:
4013614416606
External Classifications and Standards
Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4761 >> Magnet contactor, AC-switching
E-Number (Norway):
4183907
E-Number (Sweden):
3210686
Show accessory images
Accessories
No downloads available
EPLAN Data B7-30-01-80
2D & 3D Data B7-30-01-80
6.3.0.53655