B6-30-10-80
B6-30-10-80
 Loading Images..
Feedback Comments and Assessment
Excellent
Good
Poor
Cancel
Send feedback  
Back to search results
Print View..    Print to Pdf..

B6-30-10-80

GJL1211001R8100
 Loading Images..
  1. Products
  2. Low Voltage Products and Systems
  3. Control Products
  4. Contactors
  5. Mini Contactors
  1. Parts & Services
  2. Medium Voltage Products and Systems
  3. Service
  4. Spares and Consumables
  5. Parts
  6. All Spare Parts (Relays-SWG-CB)
  1. Parts & Services
  2. Medium Voltage Products and Systems
  3. Switchgear and Motor Control
  4. Gas Insulated Secondary Switchgear (SF6 free)
  5. SafePlus (SF6 free)
  6. SafePlus Air up to 12kV
  1. Parts & Services
  2. Medium Voltage Products and Systems
  3. Switchgear and Motor Control
  4. Gas Insulated Secondary Switchgear (SF6 free)
  5. SafePlus (SF6 free)
  6. SafePlus AirPlus up to 24kV
  1. Parts & Services
  2. Medium Voltage Products and Systems
  3. Switchgear and Motor Control
  4. Gas Insulated Secondary Switchgear (SF6 free)
  5. SafeRing (SF6 free)
  6. SafeRing Air up to 12kV
  1. Parts & Services
  2. Medium Voltage Products and Systems
  3. Switchgear and Motor Control
  4. Gas Insulated Secondary Switchgear (SF6 free)
  5. SafeRing (SF6 free)
  6. SafeRing AirPlus up to 24kV
  1. Parts & Services
  2. Medium Voltage Products and Systems
  3. Switchgear and Motor Control
  4. Gas Insulated Secondary Switchgear (SF6)
  5. SafePlus
  6. SafePlus IEC 36kV
  1. Parts & Services
  2. Medium Voltage Products and Systems
  3. Switchgear and Motor Control
  4. Gas Insulated Secondary Switchgear (SF6)
  5. SafePlus
  6. SafePlus IEC up to 24kV
  1. Parts & Services
  2. Medium Voltage Products and Systems
  3. Switchgear and Motor Control
  4. Gas Insulated Secondary Switchgear (SF6)
  5. SafeRing
  6. SafeRing IEC 36kV
  1. Parts & Services
  2. Medium Voltage Products and Systems
  3. Switchgear and Motor Control
  4. Gas Insulated Secondary Switchgear (SF6)
  5. SafeRing
  6. SafeRing IEC up to 24kV
- Show Less..
+ Show All..
No label translation
General Information
Extended Product Type:
B6-30-10-80
Product ID:
GJL1211001R8100
EAN:
4013614150647
Catalog Description:
B6-30-10-80 Mini Contactor 220 ... 240 V AC - 3 NO - 0 NC - Screw Terminals
Long Description:
The B6-30-10 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 4 kW (AC-3) and 20 A (AC-1) or switching of control signals. Further features are the silent coil, a switch position indication and the integrated possibility for rail or wall mounting.
  • Details
  • Downloads
  • Related Links
Go to section:
Navigate:
  • Back to top
  • Back to search results
Supplier Information - AETAD009
Country or Territory of Origin:
Germany
Lead Time:
0 day
Made To Order:
No
Warranty Return:
Product under warranty must be returned
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
AETAD009EXPU
Supplier Information - BRABB008
Country or Territory of Origin:
Germany
Lead Time:
0 day
Made To Order:
No
Warranty Return:
Product under warranty must be returned
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
BRABB008EXPU
Supplier Information - CHSEC006
Country or Territory of Origin:
Germany
Lead Time:
0 day
Made To Order:
No
Warranty Return:
Product under warranty must be returned
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
CHSEC006EXPU
Supplier Information - NOAAS001
Country or Territory of Origin:
Germany
Made To Order:
No
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
NOAAS001EXPU
Warranty Return:
Product under warranty must be returned
Ordering
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080
Popular Downloads
EPLAN Data:
9AAC201021_EPLAN
Data Sheet, Technical Information:
1SBC100214C0202
Instructions and Manuals:
2CDC102047M6801
CAD Dimensional Drawing:
2CDC001079B0201
Dimension Diagram:
GJL1200436F0001
Dimensions
Product Net Width:
52.5 mm
Product Net Depth / Length:
46.7 mm
Product Net Height:
57.5 mm
Product Net Weight:
0.175 kg
Technical
Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1

IEC/EN 60947-4-1

IEC/EN 60947-5-1

UL 60947-1

UL 60947-4-1

IEC 60335-2-40 A2L
Rated Operational Voltage:
Auxiliary Circuit 690 V AC

Auxiliary Circuit 250 V DC

Main Circuit 690 V AC

Main Circuit 220 V DC
Rated Frequency (f):
Control Circuit 400 Hz

Control Circuit 50 Hz

Control Circuit 60 Hz

Main Circuit 60 Hz

Main Circuit 50 Hz

Main Circuit DC
Conventional Free-air Thermal Current (Ith):
Main Circuit 20 A
Rated Operational Current AC-1 (Ie):
(220 / 240 V) 40 °C 20 A

(220 / 240 V) 55 °C 16 A

(380 / 440 V) 40 °C 20 A

(380 / 440 V) 55 °C 16 A

(690 V) 40 °C 6 A

(690 V) 55 °C 6 A
Rated Operational Current AC-3 (Ie):
(230 V) 55°C 9 A

(400 V) 55 °C  9 A

(500 V) 55 °C 6.5 A

(690 V) NO 55°C 3.5 A
Rated Operational Current AC-15 (Ie):
(24 V) 4 A

(120 V) 4 A

(500 V) 2 A

(220 / 240 V) 4 A

(380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie):
(24 V) 2.5 A

(110 V) 0.7 A

(220 / 240 V) 0.4 A
Rated Operational Power AC-3 (Pe):
(230 V) Three Phase 2.2 kW

(400 V) Three Phase 4 kW

(500 V) Three Phase 4 kW

(690 V) Three Phase, NO 3 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
Rated Insulation Voltage (Ui):
690 V

acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
Auxiliary Circuit 6 kV

Main Circuit 6 kV
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour

(AC-15) 600 cycles per hour

(AC-3) 600 cycles per hour

(DC-1) 600 cycles per hour

(DC-13) 600 cycles per hour

(DC-3) 600 cycles per hour
Mechanical Durability:
Nr. Operations 10000000 cycle
Minimum Switching Capacity:
Auxiliary Circuit 17 V

Auxiliary Circuit 5 mA
Coil Operating Limits:
(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
220 ... 240 V AC
Coil Consumption:
Average Holding Value 50 Hz 3.5 V·A

Average Pull-in Value 50 Hz 3.5 V·A
Power Loss:
at Rated Operating Conditions AC-1 per Pole 1 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715

TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²

Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²

Flexible 1/2x 1 ... 2.5 mm²

Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²

Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²

Flexible 1/2x 1 ... 2.5 mm²

Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²

Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²

Flexible 1/2x 1 ... 2.5 mm²

Rigid 1/2x 1 ... 4 mm²
Wire Stripping Length:
Auxiliary Circuit 9 mm

Main Circuit 9 mm
Degree of Protection:
Auxiliary Circuit Terminals IP20

Control Circuit Terminals IP20

Main Circuit Terminals IP20
Recommended Screw Driver:
M3

Pozidriv 1
Tightening Torque:
Auxiliary Circuit 0.8 ... 1.1 N·m

Control Circuit 0.8 ... 1.1 N·m

Main Circuit 0.8 ... 1.1 N·m
Terminal Type:
Screw Terminals
Mini Contactor Type:
Mini Contactor
Product Name:
Mini Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
General Use Rating UL/CSA:
(300 V AC) 12 A
Horsepower Rating UL/CSA:
(115 V AC) Single Phase 0.25 Hp

(200 V AC) Three Phase 1 Hp

(220 ... 240 V AC) Three Phase 2 Hp

(230 V AC) Single Phase 0.5 Hp

(440 ... 480 V AC) Three Phase 3 Hp

(550 ... 600 V AC) Three Phase 1 Hp
Connecting Capacity Main Circuit UL/CSA:
Stranded 1/2x 22-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA:
Stranded 1/2x 22-10 AWG
Contact Rating UL/CSA:
A600
Tightening Torque UL/CSA:
Auxiliary Circuit 7 in·lb

Control Circuit 7 in·lb

Main Circuit 7 in·lb
Full Load Amps Motor Use:
(115 V AC) Single Phase 5.8 A

(200 V AC) Three Phase 4.8 A

(220 ... 240 V AC) Three Phase 6.8 A

(230 V AC) Single Phase 4.9 A

(440 ... 480 V AC) Three Phase 4.8 A

(550 ... 600 V AC) Three Phase 1.7 A
Environmental
Ambient Air Temperature:
Operation -25 ... +55 °C

Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Resistance to Vibrations:
5g 5 ... 150 Hz
Material Compliance
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
REACH Declaration:
2CMT2021-006202
RoHS Declaration:
2CMT2021-006277
RoHS Information:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA:
2CMT2023-006525
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
End Of Life Disassembling Instructions:
1SBC100156C0269
Environmental Product Declaration - EPD:
1SAC200409H0001
Certificates and Declarations
A2L Certificate – IEC:
1SAA938000-4601
BV Certificate:
1SAA920000-0204
CB Certificate:
1SAA938000-2002
CQC Certificate:
CQC2003010304064033
Declaration of Conformity - CCC:
2020980304001854
Declaration of Conformity - CE:
1SAD101100-3101
Declaration of Conformity - UKCA:
1SAD201100-3101
DNV GL Certificate:
1SAA938000-0306
EAC Certificate:
1SAA920000-2702
KC Certificate:
1SAA938000-1501
LR Certificate:
1SAA938000-0504
RMRS Certificate:
1SAA938000-0704
UL Certificate:
E191658-19881208
Container Information
Package Level 1 Units:
box 10 piece
Package Level 1 Width:
115 mm
Package Level 1 Depth / Length:
280 mm
Package Level 1 Height:
54 mm
Package Level 1 Gross Weight:
1.82 kg
Package Level 1 EAN:
4013614412677
External Classifications and Standards
Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4761 >> Magnet contactor, AC-switching
E-Number (Finland):
3709109
E-Number (Norway):
4184000
E-Number (Sweden):
3210024
Show accessory images
Accessories
Product specific part data
No downloads available
EPLAN Data B6-30-10-80
2D & 3D Data B6-30-10-80
6.3.0.53655