CM-ENE MIN
1SVR550851R9500
4013614348082
CM-ENE MIN Liquid level relay 1n/o, 220-240VAC
The CM-ENE MIN belongs to the CM liquid level monitoring relay range. It operates with a rated control supply voltage of 220-240 V AC and has a 1 n/o output contact. It protects pumps against dry running. The output relay works according to the open-circuit principle. The sensitivity is 0-100 kOhm fixed. The device offers screw connection terminals.
1 piece
85364900
22.5 mm
78 mm
78.5 mm
0.106 kg
Draining monitoring
Dry running protection
2
0 ... 100 kΩ
220 ... 240 V AC
Supply Circuit 50/60 Hz
1 n/o contact
Screw Terminals
(230 V) 4 A
(230 V) 3 A
(24 V) 4 A
(24 V) 2 A
Measuring Circuit / Output Circuit 4 kV
Supply Circuit / Measuring Circuit 4 kV
Supply Circuit / Output Circuit 4 kV
Measuring Circuit / Output Circuit 250 V
Supply Circuit / Measuring Circuit 250 V
Supply Circuit / Output Circuit 250 V
Housing IP50
Terminals IP20
Output Circuit NO - F Type Fuses 10 A
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 2x 0.75 ... 1.5 mm²
0.6 ... 0.8 N·m
10 mm
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Output Circuit 300 V AC
B300
Flexible with Ferrule 2x 18-16 AWG
Flexible 2x 18-16 AWG
Rigid 2x 18-16 AWG
7.08 in·lb
Operation -20 ... +60 °C
Storage -40 ... +85 °C
Without Derating 2000 m
Following EU Directive 2011/65/EU
box 1 piece
23 mm
82 mm
0.118 kg
B
EC001447 - (Fill) level monitoring relay
V11.0 : 27371813
39122331
2712850
4187268
3860805