No label translation
General Information
Extended Product Type:
E1.2N 630 Ekip Dip LI 4p WMP
Product ID:
1SDA072701R1
EAN:
8015644765514
Catalog Description:
E1.2N 630 Ekip Dip LI 4p WMP
Long Description:
MOVING PART FOR C.BREAKER SACE EMAX2 E1.2N 630 FOUR-POLE WITH SOLID-STATE RELEASE IN AC EKIP/DIP-LI R 630 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED
  • Details
  • Downloads
  • Related Links
Go to section:
Navigate:
  • Back to top
  • Back to search results
ABB EcoSolutions
ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
9AKK108468A2360
Environmental Product Declaration - EPD:
9AKK108468A1900
9AKK108468A3028
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 -  76.4 %
Material Compliance
REACH Declaration:
9AKK108466A1425
RoHS Information:
9AKK108466A1424
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
Toxic Substances Control Act - TSCA:
9AKK108467A8326
SCIP:
d95d3b24-fe04-41d5-af11-e2ab4f208526 Italy
Simplified SCIP:
9d5c91c2-c878-43ec-b824-8bb55c771d39 Germany

bb294572-e1ed-4f47-b653-da56162e9a55 Belgium

d72e5ef7-3bc5-4872-93dd-f7c523584350 Sweden

8e8278fe-ff82-4051-8ff5-bddc36bb5c21 Portugal

c15bea94-b77f-4f29-b386-355fad49f9e6 Bulgaria

7501547b-e2c5-4828-a7b3-a7103294206d Czech Republic

d35e36d8-1442-4779-8a8e-052346b32a88 Poland

bb587a9d-ade5-47e3-bbf7-14257ff631f2 Poland

5194ef4d-1e0f-4c0b-9f18-05b64c2a07ff France

2a4525a8-a70c-4279-8dca-7b69be279eed Denmark

23beaa5f-6703-4c13-a361-8820510406eb Germany

d547cc3f-601c-4e55-b00a-5a068ef797c0 Germany

4fda202e-5365-4bf1-9a54-421175c9ec17 Germany

3dc93d4c-6eb3-4590-870c-34300f32e1c6 Croatia

2964b187-4dee-49a5-8a30-bbfa6cfc2ef3 France

cf873d9c-f663-4bbc-9640-b141fe8324c9 Belgium

bf7e2ac6-a60d-4a85-8fbf-1a337c661b65 Germany

0c35d49a-0a91-47ab-8a87-25e56f881501 Greece

bd4ecd2e-38fa-4ed4-8463-e71565cfec28 Netherlands

cddd50d9-1f44-4008-a39d-0c268cce24c2 Finland

7176b43a-6672-437e-8ba7-dbe70ef66c26 Estonia

20efbab6-9d87-46d9-af91-14aa35922fa0 Sweden

37fdef2d-4d59-4e04-992a-13dad522b38b Hungary

771ed70d-632c-4179-8e83-99e43e22c428 Norway

c7c78ae4-e057-422b-b8e5-aaec0fe0de26 Poland

174254bb-940f-4124-bed5-f7fce2359d83 Hungary

caf37929-6f60-4c3c-bdf5-30777b3ba74b Spain
Environmental
Environmental Information:
9AKK108467A6707
Ordering
Order Code US and Canada:
ZANNEEAA000A000000XX
EAN:
8015644765514
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090
Dimensions
Product Net Width:
348 mm
Product Net Height:
363.5 mm
Product Net Depth / Length:
271 mm
Product Net Weight:
20 kg
Container Information
Package Level 1 Units:
box 1 piece
Package Level 1 Width:
350 mm
Package Level 1 Height:
350 mm
Package Level 1 Depth / Length:
330 mm
Package Level 1 Gross Weight:
23 kg
Package Level 1 EAN:
8015644765514
Additional Information
Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W
CAD Dimensional Drawing:
1SDH001252R0065
Technical
Current Type:
AC
Electrical Durability:
Ue =< 440 V 8000 cycle

Ue = 500 ... 690 V 8000 cycle

30 cycles per hour
Mechanical Durability:
20000 cycle

60 cycles per hour
Neutral Pole Current ([%Iu]):
100 %
Number of Poles:
4P
Power Loss:
62 W
Rated Current (In):
630 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 66 kA

(230 V AC) 66 kA

(380 V AC) 66 kA

(400 V AC) 50 kA

(415 V AC) 50 kA

(440 V AC) 50 kA

(500 V AC) 50 kA

(660 V AC) 50 kA

(690 V AC) 50 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 50 kA

for 3 s 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 66 kA

(415 V AC) 66 kA

(440 V AC) 66 kA

(500 V AC) 50 kA

(525 V AC) 50 kA

(690 V AC) 50 kA
Rated Uninterrupted Current (Iu):
630 A
Rated Voltage (Ur):
690 V
Release:
Ekip Dip LI
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
IEC
Sub-type:
E1.2
Suitable for IT Networks:
Yes, 690V
Certificates and Declarations
ATEX Certificate:
No certification needed
CSA Certificate:
No certification needed
CSA Certificate (Intrinsic Safe):
No certification needed
Data Sheet, Technical Information:
1SDC200023D0209
Declaration of Conformity - CE:
9AKK106713A5546
UL Certificate:
No certification needed
VDE Certificate:
No certification needed
Mechanical Drawings:
1SDH000999R0103
Wiring Diagram:
1SDM000091R0001
Instructions and Manuals:
1SDH000999R0002
External Classifications and Standards
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
No downloads available
EPLAN DATA E1.2N 630 Ekip Dip LI 4p WMP