No label translation
General Information
Extended Product Type:
E1.2C 1250 Ekip Dip LI 4p F F
Product ID:
1SDA071461R1
EAN:
8015644753115
Catalog Description:
E1.2C 1250 Ekip Dip LI 4p F F
Long Description:
C.BREAKER SACE EMAX2 E1.2C 1250 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP/DIP-LI R 1250 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED
  • Details
  • Downloads
  • Related Links
Go to section:
Navigate:
  • Back to top
  • Back to search results
ABB EcoSolutions
ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
9AKK108468A2360
Environmental Product Declaration - EPD:
9AKK108468A1900
9AKK108468A3028
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 -  76.4 %
Material Compliance
REACH Declaration:
9AKK108466A1425
RoHS Information:
9AKK108466A1424
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
Toxic Substances Control Act - TSCA:
9AKK108467A8326
SCIP:
6fc9b804-5ee5-4bfb-b307-8ecf756a798f Italy
Simplified SCIP:
13252a01-bf0e-4785-8eac-43714503d895 Germany

9ac91839-e1fb-4407-b467-019e62128366 Belgium

be0fc17b-62ad-44a2-80f5-1c8eb423f01b Spain

c7f0cc28-6f05-4eba-8043-912c3fd91a67 Denmark

c2508775-10bc-479c-b733-e65b58ff5f84 Bulgaria

4a58e65c-583e-4b3d-a4fe-10c25874318e Germany

b94116e7-5b1f-4cff-8991-234f86df4063 Belgium

5f7a4e0b-3116-456d-aab7-3b36266f1ac7 Norway

cbcc6e91-9ec7-41ef-a6cc-6335f8880792 Germany

4935beb3-b2d0-4a1d-b4c4-c7144f2d6e9a Sweden

e2e58887-ae34-4f2d-a802-239c48dbaedb Finland

b1823fc1-63c1-4760-967b-beadaf2717fd Poland

ae9e72a7-71bf-46b6-a1b2-0d862a0e6a2f Poland

8730e3c8-3d14-444b-95a2-fc97cf910c6c Greece

c7f0cc28-6f05-4eba-8043-912c3fd91a67 Denmark

06719427-d898-41a3-9030-62a8867d2523 Germany

cbcc6e91-9ec7-41ef-a6cc-6335f8880792 Germany

8b6206cb-9a28-45ef-9160-a93215a503cd Croatia

b94116e7-5b1f-4cff-8991-234f86df4063 Belgium

0af587dc-81b7-477d-83fb-4f6d22e45869 France

06719427-d898-41a3-9030-62a8867d2523 Germany

4a58e65c-583e-4b3d-a4fe-10c25874318e Germany

038249f9-d6db-431e-8bf0-0b34d785de96 Sweden

8b6206cb-9a28-45ef-9160-a93215a503cd Croatia

e2e58887-ae34-4f2d-a802-239c48dbaedb Finland

778feb84-e533-43af-9648-14c9180c9c56 France

929a55b4-1104-4297-84a9-4c7a5f2b950c Portugal

de9b066f-3632-4425-bc9c-ffb6de3e4847 Czech Republic

5f7a4e0b-3116-456d-aab7-3b36266f1ac7 Norway

c2508775-10bc-479c-b733-e65b58ff5f84 Bulgaria

de9b066f-3632-4425-bc9c-ffb6de3e4847 Czech Republic

13252a01-bf0e-4785-8eac-43714503d895 Germany

bbacdd3d-f6cd-4b29-86ae-a5d9b8697e9a Germany

23c0726a-9743-435c-8122-498b97798c5b Hungary

0688d901-91f7-497c-bc42-4a83db487c26 Poland

9ac91839-e1fb-4407-b467-019e62128366 Belgium

778feb84-e533-43af-9648-14c9180c9c56 France

b1823fc1-63c1-4760-967b-beadaf2717fd Poland

038249f9-d6db-431e-8bf0-0b34d785de96 Sweden

bbacdd3d-f6cd-4b29-86ae-a5d9b8697e9a Germany

022f5df6-6d12-4b22-93e2-5fd81af4c891 Estonia

8730e3c8-3d14-444b-95a2-fc97cf910c6c Greece

0688d901-91f7-497c-bc42-4a83db487c26 Poland

920230d6-b07d-44ff-8b8d-5b2a580a828d Hungary

be0fc17b-62ad-44a2-80f5-1c8eb423f01b Spain

4935beb3-b2d0-4a1d-b4c4-c7144f2d6e9a Sweden

68119c28-9753-4daf-a96b-b3dd3ae87f90 Netherlands

022f5df6-6d12-4b22-93e2-5fd81af4c891 Estonia

929a55b4-1104-4297-84a9-4c7a5f2b950c Portugal

23c0726a-9743-435c-8122-498b97798c5b Hungary

920230d6-b07d-44ff-8b8d-5b2a580a828d Hungary

0af587dc-81b7-477d-83fb-4f6d22e45869 France

ae9e72a7-71bf-46b6-a1b2-0d862a0e6a2f Poland

68119c28-9753-4daf-a96b-b3dd3ae87f90 Netherlands
Environmental
Environmental Information:
9AKK108467A6707
Ordering
Order Code US and Canada:
ZACREHBA000A000000XX
EAN:
8015644753115
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090
Dimensions
Product Net Width:
280 mm
Product Net Height:
296 mm
Product Net Depth / Length:
183 mm
Product Net Weight:
16 kg
Container Information
Package Level 1 Units:
box 1 piece
Package Level 1 Width:
350 mm
Package Level 1 Height:
350 mm
Package Level 1 Depth / Length:
330 mm
Package Level 1 Gross Weight:
18 kg
Package Level 1 EAN:
8015644753115
Additional Information
Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
F
CAD Dimensional Drawing:
1SDH001252R0042
Technical
Current Type:
AC
Electrical Durability:
Ue =< 440 V 8000 cycle

Ue = 500 ... 690 V 6500 cycle

30 cycles per hour
Mechanical Durability:
20000 cycle

60 cycles per hour
Neutral Pole Current ([%Iu]):
100 %
Number of Poles:
4P
Power Loss:
122 W
Rated Current (In):
1250 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA

(230 V AC) 50 kA

(380 V AC) 50 kA

(400 V AC) 50 kA

(415 V AC) 50 kA

(440 V AC) 50 kA

(500 V AC) 42 kA

(660 V AC) 42 kA

(690 V AC) 42 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 42 kA

for 3 s 24 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 50 kA

(415 V AC) 50 kA

(440 V AC) 50 kA

(500 V AC) 42 kA

(525 V AC) 42 kA

(690 V AC) 42 kA
Rated Uninterrupted Current (Iu):
1250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M10
Release:
Ekip Dip LI
Release Type:
EL
Short-Circuit Performance Level:
C
Standards:
IEC
Sub-type:
E1.2
Suitable for IT Networks:
Yes, 690V
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
45 N·m
Certificates and Declarations
ATEX Certificate:
No certification needed
CSA Certificate:
No certification needed
CSA Certificate (Intrinsic Safe):
No certification needed
Data Sheet, Technical Information:
1SDC200023D0209
Declaration of Conformity - CE:
9AKK106713A5546
UL Certificate:
No certification needed
VDE Certificate:
No certification needed
Mechanical Drawings:
1SDH000999R0101
Wiring Diagram:
1SDM000091R0001
Instructions and Manuals:
1SDH000999R0002
External Classifications and Standards
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409