General Information
Extended Product Type:
XT1S 160 TMD 63-630 3p F F
Product ID:
1SDA067432R1
EAN:
8015644013264
Catalog Description:
XT1S 160 TMD 63-630 3p F F
Long Description:
C.BREAKER TMAX XT1S 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 63-630 A
  • Details
  • Downloads
  • Related Links
Go to section:
Navigate:
  • Back to top
  • Back to search results
ABB EcoSolutions
ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
9AKK108468A2347
Environmental Product Declaration - EPD:
9AKK108468A1890
9AKK108468A7793
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 -  55.9 %
Material Compliance
REACH Declaration:
9AKK108466A1425
RoHS Information:
9AKK108466A1424
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
Toxic Substances Control Act - TSCA:
9AKK108467A8326
SCIP:
ce8f8891-6bc3-4b61-ab84-65b55800b12c Italy
Simplified SCIP:
0f485dd2-345b-47b5-aeab-6dcc5440ef9f Germany

c9cc1f95-e9ad-45fb-af3a-537eeea9a165 Poland

1ccbd741-adb3-4f10-a52c-b1bd20a388f5 Norway

1391e5c1-5120-4220-8bb8-3d8552fe799e Finland

38d0cd2b-989e-4b24-bed5-62dffbdfaa08 Netherlands

bb463840-133b-4cbd-ad31-af6a9c57cb88 Germany

0fee1a6e-6a4d-42de-9d4c-c1b6bd41ac8f Denmark

89f9f307-8d6f-49ba-8a3f-7ac5805036d8 Germany

20fe8453-f873-4fc7-b77f-6f6e2602a0e3 Croatia

b0944749-d3ec-4d7b-ad13-5fdee17bb549 Czech Republic

b7986f4a-5532-47ea-b566-d8419c037fe4 Poland

646bb9c1-f1ff-415b-96dc-dec2582724a2 Netherlands

692513ce-7bf8-4288-b905-97ef8bd55806 Netherlands

b683d435-63d8-4f85-835c-f7d575fa2ca1 Spain

7a6ae108-4ae3-445f-9d24-67093624b36d Netherlands

fe0cc92e-2520-4b37-aee1-3e9999a6caaa Portugal

51814f2d-932c-4674-a7be-9e65af785725 Netherlands

a24511f0-eef9-47b9-a93a-be419cae331c Estonia

f9bbc942-6b2e-4f31-b653-08b461ec4b89 Greece

e736bd0c-83bf-4e74-aa67-c54fd149fd5d Sweden

c66859ea-22de-4e3f-a6ae-4d94f96182a0 Germany

0dfafdd1-adb5-4d45-90f9-6b8b900f3b89 Germany

6e73b777-5c04-4b2f-bbb0-a93d6931b927 France

a24511f0-eef9-47b9-a93a-be419cae331c Estonia

f9bbc942-6b2e-4f31-b653-08b461ec4b89 Greece

fe0cc92e-2520-4b37-aee1-3e9999a6caaa Portugal

7ac1fce6-4c9e-4303-96ba-631d35c69185 Bulgaria

c5a614be-fe83-4ba8-8ed1-005a446889af Sweden

85ebc361-f4dd-428a-9821-fab80f8db294 Poland

d289bc2c-e60b-4f5e-9237-b3c55ba8672d France

0fee1a6e-6a4d-42de-9d4c-c1b6bd41ac8f Denmark

89f9f307-8d6f-49ba-8a3f-7ac5805036d8 Germany

20fe8453-f873-4fc7-b77f-6f6e2602a0e3 Croatia

b0944749-d3ec-4d7b-ad13-5fdee17bb549 Czech Republic

b7986f4a-5532-47ea-b566-d8419c037fe4 Poland

646bb9c1-f1ff-415b-96dc-dec2582724a2 Netherlands

51814f2d-932c-4674-a7be-9e65af785725 Netherlands

7ac1fce6-4c9e-4303-96ba-631d35c69185 Bulgaria

c5a614be-fe83-4ba8-8ed1-005a446889af Sweden

7a6ae108-4ae3-445f-9d24-67093624b36d Netherlands

85ebc361-f4dd-428a-9821-fab80f8db294 Poland

d289bc2c-e60b-4f5e-9237-b3c55ba8672d France

e736bd0c-83bf-4e74-aa67-c54fd149fd5d Sweden

c66859ea-22de-4e3f-a6ae-4d94f96182a0 Germany

0dfafdd1-adb5-4d45-90f9-6b8b900f3b89 Germany

6e73b777-5c04-4b2f-bbb0-a93d6931b927 France

692513ce-7bf8-4288-b905-97ef8bd55806 Netherlands

b683d435-63d8-4f85-835c-f7d575fa2ca1 Spain

c9cc1f95-e9ad-45fb-af3a-537eeea9a165 Poland

1ccbd741-adb3-4f10-a52c-b1bd20a388f5 Norway

1391e5c1-5120-4220-8bb8-3d8552fe799e Finland

38d0cd2b-989e-4b24-bed5-62dffbdfaa08 Netherlands

bb463840-133b-4cbd-ad31-af6a9c57cb88 Germany
Environmental
Environmental Information:
9AKK108467A6707
Ordering
Order Code US and Canada:
XT1SE3063AFF000XXX
E-Number (Norway):
4309621
EAN:
8015644013264
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090
Dimensions
Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg
Container Information
Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.17 kg
Package Level 1 EAN:
8015644013264
Additional Information
Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:
1SDH001295R0008
Technical
Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour

8000 cycle
Mechanical Durability:
240 cycles per hour

25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms

CB with UVR  30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 4.3 W
Rated Current (In):
63 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
630 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC

500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 80 kA

(230 V AC) 80 kA

(240 V AC) 80 kA

(380 V AC) 50 kA

(415 V AC) 37.5 kA

(440 V AC) 25 kA

(500 V AC) 18 kA

(525 V AC) 17.5 kA

(690 V AC) 5 kA

(250 V DC) 2 Poles in Series 50 kA

(500 V DC) 3 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA

(230 V AC) 85 kA

(240 V AC) 85 kA

(380 V AC) 50 kA

(415 V AC) 50 kA

(440 V AC) 50 kA

(500 V AC) 36 kA

(525 V AC) 35 kA

(690 V AC) 8 kA

(250 V DC) 2 Poles in Series 50 kA

(500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
44.1...63 A
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m
Certificates and Declarations
ATEX Certificate:
No certification needed
Data Sheet, Technical Information:
1SDC210100D0206
1SDC210099D0206
Declaration of Conformity - CE:
9AKK106713A5532
GL Certificate:
1SDL000163R0103
LR Certificate:
1SDL000163R0100
UL Certificate:
No certification needed
VDE Certificate:
No certification needed
Dimension Diagram:
1SDH000719R0100
Mechanical Drawings:
1SDH000719R0100
Wiring Diagram:
1SDM000068R0001
Instructions and Manuals:
1SDH000719R0001
External Classifications and Standards
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409