XT1N 160 TMD 100-1000 3p F F
XT1N 160 TMD 100-1000 3p F F
 Loading Images..
Feedback Comments and Assessment
Excellent
Good
Poor
Cancel
Send feedback  
Back to search results
Print View..    Print to Pdf..

XT1N 160 TMD 100-1000 3p F F

 Loading Images..
  1. Products
  2. Low Voltage Products and Systems
  3. Circuit Breakers
  4. Moulded Case Circuit Breakers
  5. Tmax XT
  1. Parts & Services
  2. Robotics
  3. Controllers
  4. IRC5
  5. IRC5 Process Module
- Show Less..
No label translation
General Information
Extended Product Type:
XT1N 160 TMD 100-1000 3p F F
Product ID:
1SDA067416R1
EAN:
8015644013103
Catalog Description:
XT1N 160 TMD 100-1000 3p F F
Long Description:
C.BREAKER TMAX XT1N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 100-1000 A
  • Details
  • Downloads
  • Related Links
Go to section:
Navigate:
  • Back to top
  • Back to search results
Supplier Information - SEROP
Country or Territory of Origin:
Italy
ABB EcoSolutions
ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
9AKK108468A2347
Environmental Product Declaration - EPD:
9AKK108468A1890
9AKK108468A7793
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 -  55.9 %
Material Compliance
REACH Declaration:
9AKK108466A1425
RoHS Information:
9AKK108466A1424
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
Toxic Substances Control Act - TSCA:
9AKK108467A8326
SCIP:
9dc23701-0389-4d5d-9536-ba4ecc672f9f Italy
Simplified SCIP:
dd3b120b-cdd6-4746-84e1-3b6ba8deac82 Germany

8ebd8f62-f8d3-47fd-bae4-333e0a218076 Greece

db9cca29-2669-426f-bf76-0e2f3f91228f Portugal

01cd358c-7878-4350-a8cb-ad98bcdf704c Bulgaria

b0a036f2-b8f0-4f7f-aefc-8d094fa47899 Sweden

996ed7e4-edc7-4d81-acaa-2cb3aad20176 Poland

8fd3fa87-f754-4249-8c2f-b59e41939151 France

c53d77de-041e-4093-a986-0c6cc61f57c5 Sweden

84ac0468-5c88-4c5d-8651-f235b69841f9 Norway

fbb53485-dd85-4069-8b43-658e7c5756b5 Finland

d200e345-117c-45cc-aa41-8ed4a9afed60 Netherlands

1a85d563-57df-4b20-b426-89ccb3c219e0 Germany

e9fc3286-418a-43e6-a8da-5755bebb9679 Denmark

b375cf2b-78f3-4e1e-ae01-a1a61a24b8a8 Germany

d6dca289-557a-48dd-b4aa-fd4b82c36b75 Croatia

83b9a438-3162-4bc0-be90-1012a3e4b3fc Poland

4f0681cb-c9f4-4a2f-abaf-3d07ac967890 Germany

3b489665-c6a7-4f01-ac7f-d84483cd1553 France

e6c6fa22-a8fe-4514-a81d-fcf5be2a7031 Netherlands

c4a7c5cf-16cb-45a7-8b0f-07ab801af36a Spain

83b9a438-3162-4bc0-be90-1012a3e4b3fc Poland

84ac0468-5c88-4c5d-8651-f235b69841f9 Norway

fbb53485-dd85-4069-8b43-658e7c5756b5 Finland

b0a036f2-b8f0-4f7f-aefc-8d094fa47899 Sweden

2bcd0110-606e-4b4a-96e7-796264c5d0b9 Netherlands

996ed7e4-edc7-4d81-acaa-2cb3aad20176 Poland

8fd3fa87-f754-4249-8c2f-b59e41939151 France

c53d77de-041e-4093-a986-0c6cc61f57c5 Sweden

8b19cf35-ed11-4fe7-8969-08b832056cec Germany

3acf60b8-4063-465a-b3fd-a4c165e3f530 Czech Republic

5dc72b3c-ae87-4b2b-b761-495b6eb5d7eb Poland

cb2acb5b-5523-4886-9a78-19a9c1e14bee Netherlands

1216d8d6-e907-4c14-bafd-557686032dbe Netherlands

87f2c02c-07fc-4c8f-9140-875e6fa9b620 Estonia

8ebd8f62-f8d3-47fd-bae4-333e0a218076 Greece

db9cca29-2669-426f-bf76-0e2f3f91228f Portugal

8b19cf35-ed11-4fe7-8969-08b832056cec Germany

4f0681cb-c9f4-4a2f-abaf-3d07ac967890 Germany

3b489665-c6a7-4f01-ac7f-d84483cd1553 France

e6c6fa22-a8fe-4514-a81d-fcf5be2a7031 Netherlands

c4a7c5cf-16cb-45a7-8b0f-07ab801af36a Spain

2bcd0110-606e-4b4a-96e7-796264c5d0b9 Netherlands

01cd358c-7878-4350-a8cb-ad98bcdf704c Bulgaria

d200e345-117c-45cc-aa41-8ed4a9afed60 Netherlands

1a85d563-57df-4b20-b426-89ccb3c219e0 Germany

e9fc3286-418a-43e6-a8da-5755bebb9679 Denmark

b375cf2b-78f3-4e1e-ae01-a1a61a24b8a8 Germany

d6dca289-557a-48dd-b4aa-fd4b82c36b75 Croatia

3acf60b8-4063-465a-b3fd-a4c165e3f530 Czech Republic

5dc72b3c-ae87-4b2b-b761-495b6eb5d7eb Poland

cb2acb5b-5523-4886-9a78-19a9c1e14bee Netherlands

1216d8d6-e907-4c14-bafd-557686032dbe Netherlands

87f2c02c-07fc-4c8f-9140-875e6fa9b620 Estonia
Environmental
Environmental Information:
9AKK108467A6707
Ordering
E-Number (Finland):
3640527
E-Number (Norway):
4379208
E-Number (Sweden):
3182429
EAN:
8015644013103
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090
Dimensions
Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg
Container Information
Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.133 kg
Package Level 1 EAN:
8015644013103
Additional Information
Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:
1SDH001295R0008
Technical
Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour

8000 cycle
Mechanical Durability:
240 cycles per hour

25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms

CB with UVR  30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 7 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1000 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC

500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA

(230 V AC) 50 kA

(240 V AC) 50 kA

(380 V AC) 36 kA

(415 V AC) 36 kA

(440 V AC) 18 kA

(500 V AC) 15 kA

(525 V AC) 11 kA

(690 V AC) 5 kA

(250 V DC) 2 Poles in Series 36 kA

(500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA

(230 V AC) 65 kA

(240 V AC) 65 kA

(380 V AC) 36 kA

(415 V AC) 36 kA

(440 V AC) 36 kA

(500 V AC) 30 kA

(525 V AC) 22 kA

(690 V AC) 6 kA

(250 V DC) 2 Poles in Series 36 kA

(500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m
Certificates and Declarations
ATEX Certificate:
No certification needed
Data Sheet, Technical Information:
2CDC210017C0101
1SDC210100D0206
1SXF210033C2001
1SDC210099D0206
1SXF210034C2001
Declaration of Conformity - CE:
9AKK106713A5532
GL Certificate:
1SDL000163R0103
LR Certificate:
1SDL000163R0100
UL Certificate:
No certification needed
VDE Certificate:
No certification needed
Dimension Diagram:
1SDH000719R0100
Mechanical Drawings:
1SDH000719R0100
Wiring Diagram:
1SDM000068R0001
Instructions and Manuals:
1SDH000719R0001
External Classifications and Standards
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Where Used (as part of "kit")
No downloads available
EPLAN DATA XT1N 160 TMD 100-1000 3p F F
6.3.0.53655