XT1N 160 TMD 100-1000 3p F F
XT1N 160 TMD 100-1000 3p F F
 Loading Images..
Feedback Comments and Assessment
Excellent
Good
Poor
Cancel
Send feedback  
Back to search results
Print View..    Print to Pdf..

XT1N 160 TMD 100-1000 3p F F

 Loading Images..
  1. Products
  2. Low Voltage Products and Systems
  3. Circuit Breakers
  4. Moulded Case Circuit Breakers
  5. Tmax XT
  1. Products
  2. Robotics
  3. Service
  4. Spares and Consumables
  5. Parts
  1. Parts & Services
  2. Robotics
  3. Controllers
  4. IRC5
  5. IRC5 Process Module
- Show Less..
No label translation
General Information
Extended Product Type:
XT1N 160 TMD 100-1000 3p F F
Product ID:
1SDA067416R1
EAN:
8015644013103
Catalog Description:
XT1N 160 TMD 100-1000 3p F F
Long Description:
C.BREAKER TMAX XT1N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 100-1000 A
  • Details
  • Downloads
  • Related Links
Go to section:
Navigate:
  • Back to top
  • Back to search results
Supplier Information - SEROP
Country or Territory of Origin:
Italy
ABB EcoSolutions
ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
9AKK108468A2347
Environmental Product Declaration - EPD:
9AKK108468A1890
9AKK108468A7793
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 -  55.9 %
Material Compliance
REACH Declaration:
9AKK108466A1425
RoHS Declaration:
9AKK108466A1424
RoHS Information:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
Toxic Substances Control Act - TSCA:
9AKK108467A8326
SCIP:
9dc23701-0389-4d5d-9536-ba4ecc672f9f Italy
Simplified SCIP:
dd3b120b-cdd6-4746-84e1-3b6ba8deac82 Germany

8ebd8f62-f8d3-47fd-bae4-333e0a218076 Greece

db9cca29-2669-426f-bf76-0e2f3f91228f Portugal

01cd358c-7878-4350-a8cb-ad98bcdf704c Bulgaria

b0a036f2-b8f0-4f7f-aefc-8d094fa47899 Sweden

996ed7e4-edc7-4d81-acaa-2cb3aad20176 Poland

8fd3fa87-f754-4249-8c2f-b59e41939151 France

c53d77de-041e-4093-a986-0c6cc61f57c5 Sweden

84ac0468-5c88-4c5d-8651-f235b69841f9 Norway

fbb53485-dd85-4069-8b43-658e7c5756b5 Finland

d200e345-117c-45cc-aa41-8ed4a9afed60 Netherlands

1a85d563-57df-4b20-b426-89ccb3c219e0 Germany

e9fc3286-418a-43e6-a8da-5755bebb9679 Denmark

b375cf2b-78f3-4e1e-ae01-a1a61a24b8a8 Germany

d6dca289-557a-48dd-b4aa-fd4b82c36b75 Croatia

83b9a438-3162-4bc0-be90-1012a3e4b3fc Poland

4f0681cb-c9f4-4a2f-abaf-3d07ac967890 Germany

3b489665-c6a7-4f01-ac7f-d84483cd1553 France

e6c6fa22-a8fe-4514-a81d-fcf5be2a7031 Netherlands

c4a7c5cf-16cb-45a7-8b0f-07ab801af36a Spain

83b9a438-3162-4bc0-be90-1012a3e4b3fc Poland

84ac0468-5c88-4c5d-8651-f235b69841f9 Norway

fbb53485-dd85-4069-8b43-658e7c5756b5 Finland

b0a036f2-b8f0-4f7f-aefc-8d094fa47899 Sweden

2bcd0110-606e-4b4a-96e7-796264c5d0b9 Netherlands

996ed7e4-edc7-4d81-acaa-2cb3aad20176 Poland

8fd3fa87-f754-4249-8c2f-b59e41939151 France

c53d77de-041e-4093-a986-0c6cc61f57c5 Sweden

8b19cf35-ed11-4fe7-8969-08b832056cec Germany

3acf60b8-4063-465a-b3fd-a4c165e3f530 Czech Republic

5dc72b3c-ae87-4b2b-b761-495b6eb5d7eb Poland

cb2acb5b-5523-4886-9a78-19a9c1e14bee Netherlands

1216d8d6-e907-4c14-bafd-557686032dbe Netherlands

87f2c02c-07fc-4c8f-9140-875e6fa9b620 Estonia

8ebd8f62-f8d3-47fd-bae4-333e0a218076 Greece

db9cca29-2669-426f-bf76-0e2f3f91228f Portugal

8b19cf35-ed11-4fe7-8969-08b832056cec Germany

4f0681cb-c9f4-4a2f-abaf-3d07ac967890 Germany

3b489665-c6a7-4f01-ac7f-d84483cd1553 France

e6c6fa22-a8fe-4514-a81d-fcf5be2a7031 Netherlands

c4a7c5cf-16cb-45a7-8b0f-07ab801af36a Spain

2bcd0110-606e-4b4a-96e7-796264c5d0b9 Netherlands

01cd358c-7878-4350-a8cb-ad98bcdf704c Bulgaria

d200e345-117c-45cc-aa41-8ed4a9afed60 Netherlands

1a85d563-57df-4b20-b426-89ccb3c219e0 Germany

e9fc3286-418a-43e6-a8da-5755bebb9679 Denmark

b375cf2b-78f3-4e1e-ae01-a1a61a24b8a8 Germany

d6dca289-557a-48dd-b4aa-fd4b82c36b75 Croatia

3acf60b8-4063-465a-b3fd-a4c165e3f530 Czech Republic

5dc72b3c-ae87-4b2b-b761-495b6eb5d7eb Poland

cb2acb5b-5523-4886-9a78-19a9c1e14bee Netherlands

1216d8d6-e907-4c14-bafd-557686032dbe Netherlands

87f2c02c-07fc-4c8f-9140-875e6fa9b620 Estonia
Environmental
Environmental Information:
9AKK108467A6707
Ordering
E-Number (Finland):
3640527
E-Number (Norway):
4379208
E-Number (Sweden):
3182429
EAN:
8015644013103
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090
Dimensions
Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg
Container Information
Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.133 kg
Package Level 1 EAN:
8015644013103
Additional Information
Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:
1SDH001295R0008
Technical
Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour

8000 cycle
Mechanical Durability:
240 cycles per hour

25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms

CB with UVR  30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 7 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1000 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC

500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA

(230 V AC) 50 kA

(240 V AC) 50 kA

(380 V AC) 36 kA

(415 V AC) 36 kA

(440 V AC) 18 kA

(500 V AC) 15 kA

(525 V AC) 11 kA

(690 V AC) 5 kA

(250 V DC) 2 Poles in Series 36 kA

(500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA

(230 V AC) 65 kA

(240 V AC) 65 kA

(380 V AC) 36 kA

(415 V AC) 36 kA

(440 V AC) 36 kA

(500 V AC) 30 kA

(525 V AC) 22 kA

(690 V AC) 6 kA

(250 V DC) 2 Poles in Series 36 kA

(500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m
Certificates and Declarations
ATEX Certificate:
No certification needed
Data Sheet, Technical Information:
2CDC210017C0101
1SDC210100D0206
1SXF210033C2001
1SDC210099D0206
1SXF210034C2001
Declaration of Conformity - CE:
9AKK106713A5532
GL Certificate:
1SDL000163R0103
LR Certificate:
1SDL000163R0100
UL Certificate:
No certification needed
VDE Certificate:
No certification needed
Dimension Diagram:
1SDH000719R0100
Mechanical Drawings:
1SDH000719R0100
Wiring Diagram:
1SDM000068R0001
Instructions and Manuals:
1SDH000719R0001
External Classifications and Standards
ETIM 9:
EC001023 - Shunt release (for power circuit breaker)
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Where Used (as part of "kit")
No downloads available
EPLAN DATA XT1N 160 TMD 100-1000 3p F F
6.3.0.53655