AF65-30-11-11
AF65-30-11-11
 Loading Images..
Feedback Comments and Assessment
Excellent
Good
Poor
Cancel
Send feedback  
Back to search results
Print View..    Print to Pdf..

AF65-30-11-11

 Loading Images..
  1. Products
  2. Low Voltage Products and Systems
  3. Control Products
  4. Contactors
  5. Block Contactors
  6. AF Contactors
  7. AF65
  1. Parts & Services
  2. Drives
  3. Services
  4. Spares and Consumables
  5. Parts
- Show Less..
No label translation
General Information
Extended Product Type:
AF65-30-11-11
Product ID:
1SBL387001R1111
EAN:
3471523132719
Catalog Description:
AF65-30-11-11 24-60V50/60HZ 20-60VDC Contactor
Long Description:
The AF65-30-11-11 is a 3 pole - 690 V IEC or 600 UL contactor with pre-mounted auxiliary contacts and screw terminals, controlling motors up to 30 kW / 400 V AC (AC-3) or 50 hp / 480 V UL and switching power circuits up to 105 A (AC-1) or 90 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
  • Details
  • Downloads
  • Related Links
Go to section:
Navigate:
  • Back to top
  • Back to search results
Supplier Information - BRAPR001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
BRAPR001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - CHNOR001
Configuration Only:
No
Country or Territory of Origin:
France
Lead Time:
0 day
Made To Order:
No
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
CHNOR001EXPU
Warranty Return:
Product under warranty must be returned
Supplier Information - CLABB001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
CLABB001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - CNIAB001
Note:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
CNIAB001EXPU
Storage Location:
4001
Supplier Information - COABB001
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Warranty Return:
Product under warranty must be returned
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
COABB001EXPU
Storage Location:
4001
Supplier Information - DEAPRMLC
Configuration Only:
No
Country or Territory of Origin:
France
Lead Time:
0 day
Made To Order:
No
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
DEAPRMLCEXPU
Warranty Return:
Product under warranty must be returned
Supplier Information - DKSER001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
DKSER001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - DUABB001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
DUABB001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - DUABB003
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
DUABB003EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - EESER001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
EESER001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - EGAUT001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
EGAUT001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - ESATD001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
ESATD001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - FIPSE
Note:
No
Product Availability Class:
Standard delivery time 19 day
Lead Time:
19 day
Country or Territory of Origin:
France
Supplier Information - FISER001
Configuration Only:
No
Country or Territory of Origin:
France
Lead Time:
0 day
Made To Order:
No
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
FISER001EXPU
Warranty Return:
Product under warranty must be returned
Supplier Information - FRAUT001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
FRAUT001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - GBINS001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
GBINS001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - GRABB001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
GRABB001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - INABB039
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
INABB039EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - INABBRLC
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
INABBRLCEXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - ITIND002
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
ITIND002EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - NLABB021
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
NLABB021EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - NOATDRLC
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
NOATDRLCEXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - SGIND002
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
SGIND002EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - TRDMD001
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Warranty Return:
Product under warranty must be returned
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
TRDMD001EXPU
Storage Location:
4001
Supplier Information - USABB251
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
19 day
Made To Order:
No
Note:
No
Product Availability Class:
Standard delivery time 19 day
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
USABB251EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - ZATAD021
Configuration Only:
No
Country or Territory of Origin:
France
Lead Time:
0 day
Made To Order:
No
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
ZATAD021EXPU
Warranty Return:
Product under warranty must be returned
Ordering
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900
Popular Downloads
EPLAN Data:
9AAC175974_EPLAN
Data Sheet, Technical Information:
1SBC100214C0202
Instructions and Manuals:
1SBC101036M6801
Instructions and Manuals (Part 2):
1SAC200017M0002
CAD Dimensional Drawing:
2CDC001079B0201
Dimensions
Product Net Width:
67 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
1.01 kg
Technical
Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Auxiliary Circuit 690 V

Main Circuit 690 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz

Control Circuit 50 / 60 Hz

Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A

acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A

(690 V) 60 °C 90 A

(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A

(440 V) 60 °C 65 A

(500 V) 60 °C 55 A

(690 V) 60 °C 39 A

(380 / 400 V) 60 °C 65 A

(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A

(440 V) 60 °C 65 A

(500 V) 60 °C 55 A

(690 V) 60 °C 39 A

(380 / 400 V) 60 °C 65 A

(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-15 (Ie):
(500 V) 2 A

(690 V) 2 A

(24 / 127 V) 6 A

(220 / 240 V) 4 A

(400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A

(110 V) 2 Poles in Series, 60 °C 90 A

(110 V) 2 Poles in Series, 70 °C 80 A

(110 V) 3 Poles in Series, 40 °C 105 A

(110 V) 3 Poles in Series, 60 °C 90 A

(110 V) 3 Poles in Series, 70 °C 80 A

(220 V) 3 Poles in Series, 40 °C 105 A

(220 V) 3 Poles in Series, 60 °C 90 A

(220 V) 3 Poles in Series, 70 °C 80 A

(72 V) 1-Pole, 40 °C 105 A

(72 V) 1-Pole, 60 °C 90 A

(72 V) 1-Pole, 70 °C 80 A

(72 V) 2 Poles in Series, 40 °C 105 A

(72 V) 2 Poles in Series, 60 °C 90 A

(72 V) 2 Poles in Series, 70 °C 80 A

(72 V) 3 Poles in Series, 40 °C 105 A

(72 V) 3 Poles in Series, 60 °C 90 A

(72 V) 3 Poles in Series, 70 °C 80 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A

(110 V) 2 Poles in Series, 60 °C 90 A

(110 V) 2 Poles in Series, 70 °C 80 A

(110 V) 3 Poles in Series, 40 °C 105 A

(110 V) 3 Poles in Series, 60 °C 90 A

(110 V) 3 Poles in Series, 70 °C 80 A

(220 V) 3 Poles in Series, 40 °C 105 A

(220 V) 3 Poles in Series, 60 °C 90 A

(220 V) 3 Poles in Series, 70 °C 80 A

(72 V) 1-Pole, 40 °C 105 A

(72 V) 1-Pole, 60 °C 90 A

(72 V) 1-Pole, 70 °C 80 A

(72 V) 2 Poles in Series, 40 °C 105 A

(72 V) 2 Poles in Series, 60 °C 90 A

(72 V) 2 Poles in Series, 70 °C 80 A

(72 V) 3 Poles in Series, 40 °C 105 A

(72 V) 3 Poles in Series, 60 °C 90 A

(72 V) 3 Poles in Series, 70 °C 80 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A

(110 V) 2 Poles in Series, 60 °C 90 A

(110 V) 2 Poles in Series, 70 °C 80 A

(110 V) 3 Poles in Series, 40 °C 105 A

(110 V) 3 Poles in Series, 60 °C 90 A

(110 V) 3 Poles in Series, 70 °C 80 A

(220 V) 3 Poles in Series, 40 °C 105 A

(220 V) 3 Poles in Series, 60 °C 90 A

(220 V) 3 Poles in Series, 70 °C 80 A

(72 V) 1-Pole, 40 °C 105 A

(72 V) 1-Pole, 60 °C 90 A

(72 V) 1-Pole, 70 °C 80 A

(72 V) 2 Poles in Series, 40 °C 105 A

(72 V) 2 Poles in Series, 60 °C 90 A

(72 V) 2 Poles in Series, 70 °C 80 A

(72 V) 3 Poles in Series, 40 °C 105 A

(72 V) 3 Poles in Series, 60 °C 90 A

(72 V) 3 Poles in Series, 70 °C 80 A
Rated Operational Current DC-13 (Ie):
(24 V) 6 A / 144 W

(48 V) 2.8 A / 134 W

(72 V) 1 A / 72 W

(110 V) 0.55 A / 60 W

(125 V) 0.55 A / 69 W

(220 V) 0.27 A / 60 W

(250 V) 0.27 A / 68 W

(400 V) 0.15 A / 60 W

(500 V) 0.13 A / 65 W

(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW

(415 V) 37 kW

(440 V) 37 kW

(500 V) 37 kW

(690 V) 37 kW

(380 / 400 V) 30 kW

(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW

(440 V) 37 kW

(500 V) 37 kW

(690 V) 37 kW

(380 / 400 V) 30 kW

(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A

for 0.1 s 140 A

for 1 s 100 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V

acc. to IEC 60947-5-1 690 V

acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour

(AC-15) 1200 cycles per hour

(AC-2 / AC-4) 150 cycles per hour

(AC-3) 1200 cycles per hour

(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 24 ... 60 V

60 Hz 24 ... 60 V

DC Operation 20 ... 60 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A

Average Holding Value 50 Hz 4 V·A

Average Holding Value 60 Hz 4 V·A

Average Holding Value DC 2 W

Average Holding Value, from Warm State 2 W
Power Loss:
at 6 A per Pole 0.1 W

at Rated Operating Conditions AC-1 per Pole 7 W

at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms

Between Coil De-energization and NO Contact Opening 17 ... 100 ms

Between Coil Energization and NC Contact Opening 38 ... 95 ms

Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715

TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²

Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²

Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²

Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²

Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²

Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²

Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²

Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²

Rigid Solid 1/2x 1 ... 2.5 mm²

Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Auxiliary Circuit 10 mm

Control Circuit 10 mm

Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Auxiliary Circuit 1.2 N·m

Control Circuit 1.2 N·m

Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp

(200 ... 208 V AC) Three Phase 20 hp

(220 ... 240 V AC) Three Phase 25 hp

(240 V AC) Single Phase 15 hp

(440 ... 480 V AC) Three Phase 50 hp

(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG

Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Auxiliary Circuit 11 in·lb

Control Circuit 11 in·lb

Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A

(200 ... 208 V AC) Three Phase 62.1 A

(220 ... 240 V AC) Three Phase 68 A

(240 V AC) Single Phase 68 A

(440 ... 480 V AC) Three Phase 65 A

(550 ... 600 V AC) Three Phase 62 A
Environmental
Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C

Close to Contactor without Thermal O/L Relay -40 ... 70 °C

Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g

Closed, Shock Direction: B1 25 g

Closed, Shock Direction: B2 15 g

Closed, Shock Direction: C1 25 g

Closed, Shock Direction: C2 25 g

Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3
Material Compliance
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
REACH Declaration:
2CMT2021-006202
RoHS Declaration:
2CMT2021-006277
RoHS Information:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
d9555361-1018-40d6-8cb6-e7f85987becf France
Simplified SCIP:
dd548c6c-8a3f-4476-90e3-f9f83be0033b Germany

31e74b10-7e43-4a14-bef4-ba0a183e22e6 Poland

7f89b93f-0ece-483b-b26c-81e41e5c53ea Norway

924eba1e-bc3f-4014-b04c-f29972c71585 Germany

5359db27-b2ad-4000-823a-b636cf3b6231 Poland

d528f1da-4f9e-4d07-904c-9f15fbe5a5d5 Netherlands

2819f27d-e610-4db5-a32b-e2bd4334e7bd Hungary

f37ef345-30aa-49ef-9598-66cefb0dd647 Estonia

4213a7e1-e3d7-4a64-9a3e-1d2a59f04706 Italy

0e54bdeb-83e9-4b3b-a93f-7d1c4b59b1db Denmark

1bcf7450-2b2e-4b5b-be66-433f7a943ca9 Germany

df94d61c-6fa2-4c2a-989d-38f1adb140f3 Croatia

8897530c-0c09-4f97-84e3-923277a4b557 Czech Republic

4ab3341d-b66c-44b1-9761-4127f45effdc Bulgaria

fd24c700-2cfa-47ab-8024-a29d13452d92 Sweden

cd46be2d-d45a-4abc-b1a9-db0cdae0eee8 Poland

cadd27a0-1b24-4ead-8be5-861fc09ac579 France

1fdf8b88-59ca-4d2f-b310-602c0b989fec Sweden

c8dff54d-4c97-4b68-b235-a29e3104acfb Germany

bbff211e-c9fb-4a99-8ac6-ad91769868d2 Germany

27919ef0-8e9e-4279-9711-a13b1e8355ba Hungary

2f698bde-c79c-4be4-ace3-e3eaad848aa5 Greece

d06b297f-54e4-4c14-8db5-a20a39f42802 Portugal

075167b1-d405-4e52-85d6-e10c2049cc96 Spain

4e75e7cc-35f7-4d0d-9e96-fcdc69c42f71 Belgium

4222f957-ffd0-4155-9060-dee2baf2a32d Finland

9a9750a6-82af-4bee-8f7f-eaed4f33f23d Belgium
Toxic Substances Control Act - TSCA:
2CMT2023-006525
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
1SBC101081M6801
Environmental Product Declaration - EPD:
1SBD250584E1000
Improved Energy Efficiency for Customers:
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line

Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Certificates and Declarations
A2L Certificate – UL:
9AKK108469A4890
9AKK108469A4892
ABS Certificate:
ABS_20-2060694-PDA
BV Certificate:
BV_2634H36994A
CB Certificate:
SE-115941
CCC Certificate:
CCC_2024010304648524
Declaration of Conformity - CCC:
2020980304001256
2020980304001074
Declaration of Conformity - CE:
1SBD250000U1000
Declaration of Conformity - UKCA:
1SBD250031U1000
DNV Certificate:
DNV_TAE00001AF-4
KC Certificate:
KC_HW02016-15003C
LR Certificate:
LRS_LR23403517TA-02
RINA Certificate:
RINA_ELE084013XG
RMRS Certificate:
RMRS_1802705280
UL Certificate:
UL-US-L312527-1141-10303102-19
UL-CA-L312527-4141-10303102-19
UL Listing Card:
UL_E312527
Container Information
Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.11 kg
Package Level 1 EAN:
3471523132719
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
11.1 kg
External Classifications and Standards
Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707062
No downloads available
EPLAN Data AF65-30-11-11
2D & 3D Data AF65-30-11-11
6.3.0.53655