AF09-30-10-11

 Loading Images..
  1. Products
  2. Low Voltage Products and Systems
  3. Control Products
  4. Contactors
  5. Block Contactors
  6. AF Contactors
  7. AF09
- Show Less..
No label translation
General Information
Extended Product Type:
AF09-30-10-11
Product ID:
1SBL137001R1110
EAN:
3471523110014
Catalog Description:
AF09-30-10-11 24-60V50/60HZ 20-60VDC Contactor
Long Description:
The AF09-30-10-11 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 4 kW / 400 V AC (AC-3) or 5 hp / 480 V UL and switching power circuits up to 25 A (AC-1) or 25 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
  • Details
  • Downloads
  • Related Links
Go to section:
Navigate:
  • Back to top
  • Back to search results
Supplier Information - BRAPR001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
BRAPR001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - CHABB001
Country or Territory of Origin:
Switzerland
Lead Time:
0 day
Made To Order:
No
Product Sales Status:
Active
Quote Only:
No
Stocked At Warehouses:
CHABB001EXPU
Warranty Return:
Product under warranty must be returned
Supplier Information - CHNOR001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
0 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
CHNOR001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - CLABB001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
CLABB001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - CNIAB001
Note:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
CNIAB001EXPU
Storage Location:
4001
Supplier Information - COABB001
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Warranty Return:
Product under warranty must be returned
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
COABB001EXPU
Storage Location:
4001
Supplier Information - DEAPRMLC
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
0 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
DEAPRMLCEXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - DKSER001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
DKSER001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - DUABB001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
DUABB001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - DUABB003
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
DUABB003EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - EESER001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
EESER001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - EGAUT001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
EGAUT001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - ESATD001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
ESATD001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - FIPSE
Note:
No
Replacement Part ID:
3AUA0000124990
Product Availability Class:
Replaced
Lead Time:
999 day
Country or Territory of Origin:
France
Supplier Information - FISER001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
0 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
FISER001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - FRAUT001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
FRAUT001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - GBINS001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
GBINS001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - GRABB001
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
GRABB001EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - INABB039
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
INABB039EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - INABBRLC
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
INABBRLCEXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - ITIND002
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
ITIND002EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - NLABB021
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
NLABB021EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - NOATDRLC
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
0 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
NOATDRLCEXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - SGIND002
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
SGIND002EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - TRDMD001
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Warranty Return:
Product under warranty must be returned
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
TRDMD001EXPU
Storage Location:
4001
Supplier Information - USABB251
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
999 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
USABB251EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Supplier Information - ZATAD021
Configuration Only:
No
Country or Territory of Origin:
France
Criticality:
No
Lead Time:
0 day
Made To Order:
No
Note:
No
Product Availability Class:
Replaced
Product Sales Status:
Active
Quote Only:
No
Replacement Part ID:
3AUA0000124990
Stocked At Warehouses:
ZATAD021EXPU
Storage Location:
4001
Warranty Return:
Product under warranty must be returned
Ordering
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900
Popular Downloads
EPLAN Data:
9AAC159656_EPLAN
Data Sheet, Technical Information:
1SBC100214C0202
Instructions and Manuals:
1SBC101027M6801
Instructions and Manuals (Part 2):
1SAC200017M0002
CAD Dimensional Drawing:
2CDC001079B0201
Dimensions
Product Net Width:
45 mm
Product Net Depth / Length:
77 mm
Product Net Height:
86 mm
Product Net Weight:
0.27 kg
Technical
Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage:
Auxiliary Circuit 690 V

Main Circuit 690 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz

Control Circuit 50 / 60 Hz

Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A

acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 25 A

(690 V) 60 °C 25 A

(690 V) 70 °C 22 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 9 A

(440 V) 60 °C 9 A

(500 V) 60 °C 9.5 A

(690 V) 60 °C 7 A

(380 / 400 V) 60 °C 9 A

(220 / 230 / 240 V) 60 °C 9 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 9 A

(440 V) 60 °C 9 A

(500 V) 60 °C 9.5 A

(690 V) 60 °C 7 A

(380 / 400 V) 60 °C 9 A

(220 / 230 / 240 V) 60 °C 9 A
Rated Operational Current AC-15 (Ie):
(500 V) 2 A

(690 V) 2 A

(24 / 127 V) 6 A

(220 / 240 V) 4 A

(400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie):
(110 V) 1-Pole, 40 °C 10 A

(110 V) 1-Pole, 60 °C 10 A

(110 V) 1-Pole, 70 °C 10 A

(110 V) 2 Poles in Series, 40 °C 25 A

(110 V) 2 Poles in Series, 60 °C 25 A

(110 V) 2 Poles in Series, 70 °C 22 A

(110 V) 3 Poles in Series, 40 °C 25 A

(110 V) 3 Poles in Series, 60 °C 25 A

(110 V) 3 Poles in Series, 70 °C 22 A

(220 V) 2 Poles in Series, 40 °C 10 A

(220 V) 2 Poles in Series, 60 °C 10 A

(220 V) 2 Poles in Series, 70 °C 10 A

(220 V) 3 Poles in Series, 40 °C 25 A

(220 V) 3 Poles in Series, 60 °C 25 A

(220 V) 3 Poles in Series, 70 °C 22 A

(72 V) 1-Pole, 40 °C 25 A

(72 V) 1-Pole, 60 °C 25 A

(72 V) 1-Pole, 70 °C 22 A

(72 V) 2 Poles in Series, 40 °C 25 A

(72 V) 2 Poles in Series, 60 °C 25 A

(72 V) 2 Poles in Series, 70 °C 22 A

(72 V) 3 Poles in Series, 40 °C 25 A

(72 V) 3 Poles in Series, 60 °C 25 A

(72 V) 3 Poles in Series, 70 °C 22 A
Rated Operational Current DC-3 (Ie):
(110 V) 1-Pole, 40 °C 6 A

(110 V) 1-Pole, 60 °C 6 A

(110 V) 1-Pole, 70 °C 6 A

(110 V) 2 Poles in Series, 40 °C 25 A

(110 V) 2 Poles in Series, 60 °C 25 A

(110 V) 2 Poles in Series, 70 °C 22 A

(110 V) 3 Poles in Series, 40 °C 25 A

(110 V) 3 Poles in Series, 60 °C 25 A

(110 V) 3 Poles in Series, 70 °C 22 A

(220 V) 2 Poles in Series, 40 °C 6 A

(220 V) 2 Poles in Series, 60 °C 6 A

(220 V) 2 Poles in Series, 70 °C 6 A

(220 V) 3 Poles in Series, 40 °C 25 A

(220 V) 3 Poles in Series, 60 °C 25 A

(220 V) 3 Poles in Series, 70 °C 22 A

(72 V) 1-Pole, 40 °C 25 A

(72 V) 1-Pole, 60 °C 25 A

(72 V) 1-Pole, 70 °C 22 A

(72 V) 2 Poles in Series, 40 °C 25 A

(72 V) 2 Poles in Series, 60 °C 25 A

(72 V) 2 Poles in Series, 70 °C 22 A

(72 V) 3 Poles in Series, 40 °C 25 A

(72 V) 3 Poles in Series, 60 °C 25 A

(72 V) 3 Poles in Series, 70 °C 22 A
Rated Operational Current DC-5 (Ie):
(110 V) 1-Pole, 40 °C 4 A

(110 V) 1-Pole, 60 °C 4 A

(110 V) 1-Pole, 70 °C 4 A

(110 V) 2 Poles in Series, 40 °C 10 A

(110 V) 2 Poles in Series, 60 °C 10 A

(110 V) 2 Poles in Series, 70 °C 10 A

(110 V) 3 Poles in Series, 40 °C 25 A

(110 V) 3 Poles in Series, 60 °C 25 A

(110 V) 3 Poles in Series, 70 °C 22 A

(220 V) 2 Poles in Series, 40 °C 4 A

(220 V) 2 Poles in Series, 60 °C 4 A

(220 V) 2 Poles in Series, 70 °C 4 A

(220 V) 3 Poles in Series, 40 °C 9 A

(220 V) 3 Poles in Series, 60 °C 9 A

(220 V) 3 Poles in Series, 70 °C 9 A

(72 V) 1-Pole, 40 °C 9 A

(72 V) 1-Pole, 60 °C 9 A

(72 V) 1-Pole, 70 °C 9 A

(72 V) 2 Poles in Series, 40 °C 25 A

(72 V) 2 Poles in Series, 60 °C 25 A

(72 V) 2 Poles in Series, 70 °C 22 A

(72 V) 3 Poles in Series, 40 °C 25 A

(72 V) 3 Poles in Series, 60 °C 25 A

(72 V) 3 Poles in Series, 70 °C 22 A
Rated Operational Current DC-13 (Ie):
(24 V) 6 A / 144 W

(48 V) 2.8 A / 134 W

(72 V) 1 A / 72 W

(110 V) 0.55 A / 60 W

(125 V) 0.55 A / 69 W

(220 V) 0.27 A / 60 W

(250 V) 0.27 A / 68 W

(400 V) 0.15 A / 60 W

(500 V) 0.13 A / 65 W

(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe):
(400 V) 4 kW

(415 V) 4 kW

(440 V) 4 kW

(500 V) 5.5 kW

(690 V) 5.5 kW

(380 / 400 V) 4 kW

(220 / 230 / 240 V) 2.2 kW
Rated Operational Power AC-3e (Pe):
(415 V) 4 kW

(440 V) 4 kW

(500 V) 5.5 kW

(690 V) 5.5 kW

(380 / 400 V) 4 kW

(220 / 230 / 240 V) 2.2 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A

for 0.1 s 140 A

for 1 s 100 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V

acc. to IEC 60947-5-1 690 V

acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour

(AC-15) 1200 cycles per hour

(AC-2 / AC-4) 300 cycles per hour

(AC-3) 1200 cycles per hour

(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 24 ... 60 V

60 Hz 24 ... 60 V

DC Operation 20 ... 60 V
Power Loss:
at 6 A per Pole 0.1 W

at Rated Operating Conditions AC-1 per Pole 0.8 W

at Rated Operating Conditions AC-3 per Pole 0.1 W
Operate Time:
Between Coil De-energization and NC Contact Closing 13 ... 98 ms

Between Coil De-energization and NO Contact Opening 11 ... 95 ms

Between Coil Energization and NC Contact Opening 38 ... 90 ms

Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715

TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied):
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 0.75 ... 6 mm²

Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²

Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²

Rigid Solid 1/2x 1 ... 4 mm²

Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²

Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²

Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²

Rigid Solid 1/2x 1 ... 2.5 mm²

Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²

Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²

Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²

Rigid Solid 1/2x 1 ... 2.5 mm²

Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Auxiliary Circuit 10 mm

Control Circuit 10 mm

Main Circuit 10 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque:
Auxiliary Circuit 1.2 N·m

Control Circuit 1.2 N·m

Main Circuit 1.5 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor
Technical UL/CSA
NEMA Size:
00
Continuous Current Rating NEMA:
9 A
Horsepower Rating NEMA:
(115 V AC) Single Phase 1/3 Hp

(200 V AC) Three Phase 1-1/2 Hp

(230 V AC) Single Phase 1 Hp

(230 V AC) Three Phase 1-1/2 Hp

(460 V AC) Three Phase 2 Hp

(575 V AC) Three Phase 2 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 25 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 3/4 hp

(200 ... 208 V AC) Three Phase 2 hp

(220 ... 240 V AC) Three Phase 2 hp

(240 V AC) Single Phase 1-1/2 hp

(440 ... 480 V AC) Three Phase 5 hp

(550 ... 600 V AC) Three Phase 7-1/2 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Solid 1/2x 16-10 AWG

Rigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG

Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG

Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Auxiliary Circuit 11 in·lb

Control Circuit 11 in·lb

Main Circuit 13 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 13.8 A

(200 ... 208 V AC) Three Phase 7.8 A

(220 ... 240 V AC) Three Phase 6.8 A

(240 V AC) Single Phase 10 A

(440 ... 480 V AC) Three Phase 7.6 A

(550 ... 600 V AC) Three Phase 9 A
Environmental
Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C

Close to Contactor without Thermal O/L Relay -40 ... 70 °C

Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: B1 25 g

Open, Shock Direction: B1 5 g

Shock Direction: A 30 g

Shock Direction: B2 15 g

Shock Direction: C1 25 g

Shock Direction: C2 25 g
Resistance to Vibrations:
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree:
3
Material Compliance
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
REACH Declaration:
2CMT2021-006202
RoHS Information:
2CMT2021-006277
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
fd4714ff-9365-48a3-94a4-2bebfae11f23 China
Simplified SCIP:
8297a722-cc0f-4782-a8f8-075acea41bd6 Spain

60c3dbdc-391e-4daf-9a85-70e3bd0d2ea0 Croatia

0bb95f7e-5bd1-4d7f-b192-2477a25d35da Czech Republic

0b055dbd-1066-4155-a4d4-3771b2c41d57 France

2f7a69c0-b1af-42e2-8d87-80f8ee6b4b25 Germany

b217d838-e5ce-4026-978c-a13ceece6013 Germany

1f0a558a-9d04-4edd-b827-65ac41a26dcc Sweden

2045ed6b-b82b-4628-90cd-d4e7f27bb979 Germany

880d376c-4f31-4f54-b579-aab4c5291566 Poland

75051088-0f2d-4586-871a-6331dd71d145 France

d551d6e5-5f59-4717-867a-b2bc44c17f6b Sweden

ac2002f8-634f-49f3-9820-e719cf270af6 Denmark

5abac707-494a-4531-b610-fb9643ebba41 Germany

736597e3-e353-4116-b956-c6c7b4698b4b Bulgaria

5b8d698d-7c0a-4e4b-8e45-4e67bb7a8c3a Estonia

bdb7092f-5d60-4ec6-9da8-e559b8617f36 Finland

31c30f9a-d89e-4369-8c43-e3d693e857ec Hungary

81bc28c3-da00-43f3-88e4-8d2dbf3fdc09 Hungary

91d5fca5-b899-468c-a97a-4cdf403f4a58 Norway

20d8f677-c436-4f8f-8fdc-90f414d5bf1f Netherlands

c6fee10d-6aa1-4cd6-8dc6-e09fec5969dd Belgium

b2f25054-3b81-43fb-b349-fb478b0c00c1 Greece

35fb5949-f388-41ae-9d4f-b963db63e20a Portugal

b433b770-8005-4c63-9194-9e95ab1d890a Poland

2e4f67af-ba3e-4f23-8231-a16fc7eaf9aa Germany

fc32984e-d501-4530-a019-c70a65038877 Poland

52949e89-943e-45a7-83b4-a076ae89ea4c Belgium
Toxic Substances Control Act - TSCA:
2CMT2023-006525
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
End Of Life Disassembling Instructions:
1SBC101080M6801
Environmental Product Declaration - EPD:
1SBD250584E3000
2TFP200035A1001
Sustainable Material Content in Packaging (wt. %):
Recycled Cardboard -  86 %
Sustainable Material Content in Product (wt. %):
Recycled Metal -  28 %
Certificates and Declarations
A2L Certificate – UL:
9AKK108469A4875
9AKK108469A4879
ABS Certificate:
ABS_20-2060694-PDA
BV Certificate:
BV_2634H24898C0
CB Certificate:
CB_SE-113345
CCC Certificate:
CCC_2010010304445624
CQC Certificate:
CQC2010010304445624
CQC2020010304298240
Declaration of Conformity - CCC:
2020980304001253
2020980304001082
Declaration of Conformity - CE:
1SBD250000U1000
Declaration of Conformity - UKCA:
1SBD250031U1000
DNV Certificate:
DNV_TAE00001AF-4
GOST Certificate:
GOST_POCCFR.ME77.B07175.pdf
KC Certificate:
KC_HW02016-15004C
LR Certificate:
LRS_LR23403517TA-02
RINA Certificate:
RINA_ELE142224XG
RMRS Certificate:
RMRS_1802705280
UL Certificate:
UL-US-2150887-5
UL-CA-2142658-5
UL Listing Card:
E312527
Container Information
Package Level 1 Units:
box 1 piece
Package Level 1 Width:
87 mm
Package Level 1 Depth / Length:
79 mm
Package Level 1 Height:
47 mm
Package Level 1 Gross Weight:
0.27 kg
Package Level 1 EAN:
3471523110014
Package Level 2 Units:
box 27 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
315 mm
Package Level 2 Gross Weight:
7.29 kg
External Classifications and Standards
Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3705800
E-Number (Sweden):
3210016
No downloads available
EPLAN Data AF09-30-10-11
2D & 3D Data AF09-30-10-11
6.3.0.53655